Have any questions?
+1 376-226-3126
info@stylemixthemes.com

ULTIMO

ULTIMO

AUTOMATIC SLIDING DOOR SENSOR WITH EXTENDED / ENHANCED SAFETY

Categories: , Tag:
AUTOMATIC SLIDING DOOR SENSOR WITH EXTENDED / ENHANCED SAFETY

BEA’s ULTIMOTM is a dual technology sensor with flexible safety features for automatic sliding doors. The microwave motion field activates as people or objects approach the door. Meanwhile, three adjustable infrared curtains, each with 32 spots of detection, ensure the safety of pedestrians passing through the door opening.

ULTIMO offers advanced presence detection using ULTI-SHIELD technology, which provides uniform sensitivity across the safety curtains. ULTI-SHIELD technology allows for extended or enhanced infrared curtain positioning, ensures no loss of detection and immunities to environmental disturbances.

The combination of flexible and precise detection fields complements the door’s performance – making ULTIMO ideal for high-traffic environments in hospitals, hotels, airports or retail facilities.

MOUNTING HEIGHT 6’6″ – 11’6″
DETECTION MODE Motion and Presence
TECHNOLOGY Microwave Doppler Radar and Active Infrared (AIR) with Background Analysis
RADAR DETECTION SPEED (MIN) 2 in / s
AIR RESPONSE TIME (TYP.) < 200 ms (max. 500 ms)
RADAR TRANSMITTER
FREQUENCY
RADIATED POWER
POWER DENSITY
LOBE ANGLES
24.150 GHz
< 20 dBM EIRP
< 5 mW / cm2
0 – 45º (typical adjustment), default 25º
AIR SPOTS
SIZE
NUMBER OF SPOTS
NUMBER OF CURTAINS
CURTAIN ANGLES
2” × 2” (typ.)
max. 32 per curtain
3
-3 – 11º, default 0º
RELAY OUTPUT
MAX. CONTACT VOLTAGE
MAX. CONTACT CURRENT
HOLD TIME
Electro-mechanical-relay (potential and polarity free)
30 VDC
1 A
0.5 – 9 s
OPTOFET OUTPUT
MAX. CONTACT VOLTAGE
MAX. CONTACT CURRENT
HOLD TIME
Solid-state-relay (potential and polarity free)
42 VAC / VDC
400 mA
0.3 – 1 s
TEST / MONITORING INPUT
SENSITIVITY
RESPONSE TIME ON REQUEST
Low: < 1 V; High: > 10 V (max. 30 V)
Typical: < 5 ms
SUPPLY VOLTAGE 12 – 24 VAC ±10%
12 – 30 VDC ±10%
POWER CONSUMPTION < 3.2 W
TEMPERATURE RANGE* -13 – 131 °F
0 – 95% relative humidity, non-condensing
CABLE LENGTH / GAUGE 10’ / 26 AWG
DEGREE OF PROTECTION IP54
NORM CONFORMITY R&TTE 1999 / 5 / EC; MD 2006 / 42 / EC;
LVD 2006 / 95 / EC; ROHS 2 2011 / 65 / EU

Enquiry Form